CARBO HPT

A safe, non-toxic treatment, essential for your health, beauty and physical fitness.

Latest-generation, portable easy-tech device

Our CARBO HPT technology is presented within the second-level Master's program in Aesthetic Medicine at the University of Siena, Director: Prof. Cesare Brandi — the oldest Italian Master's program in aesthetic medicine, now in its 11th edition.
https://www.unisi.it/didattica/post-laurea/masters/medicina-estetica-mame-5

...

  • Latest-generation easy-tech tabletop device for medical carbon dioxide (CO2) microinjections administered subcutaneously and intradermally.

  • Dedicated software with standard and customizable programs

  • Feedback control system with digital sensors for temperature, over/under pressure, filtering and CO2 delivery

  • Internal reservoir made of sterile material

  • "N.P.S." (No Pain System) — thanks to a special pair of patented proportional valves controlled by an internal microprocessor-driven (algorithm-managed) system that governs their opening — and therefore the delivery rate and output gas temperature, fully respecting the thermal expansion coefficient of the gas — this can be considered a pain-free therapy system.

  • Individually packaged, sterile, single-use needle-free tubing (25-27-28-30G 13mm needle)

  • Device compliant with current European regulations, certified Medical Device CE 0425 class IIb, registered with the Italian Ministry of Health BD/RDM 763147 – CND Z12040299.

  • Authorized Certification Body

Our Device in Detail

...

Video Demonstrations

...

Accessories

Accessories for the CARBO HPT Device

Pressure regulator
"Start/Pause" pedal
Hose with connection valve and related spore filter
Carrying case

...

Applications and effects
    • Treatment of cellulite and localized fat deposits
    • Pre/post-surgical treatment
    • Skin revitalization
    • Vulvar rejuvenation
    • Improves tissue oxygenation
    • Improved circulation
    • Arterial vasodilation
    • Treatment of patients with arterial disease, microcirculatory stasis (moderate venous insufficiency) in angiology
    • Treatment of arthro-rheumatic conditions and periarthritis in orthopedics
Technical data
  • Power supply: 230 Vac 50/60 Hz
  • Power consumption: 50VA, Fuses 2x 2T1A
  • Input gas pressure: 1.5 to 3.8 bar max
  • Deliverable flow: from 1 cc/15sec to 150 cc/15sec (600 cc/min)
  • Display: Color touch display – 10.4" color screen
  • Operating temperature: 30 to 42°C
  • Operating relative humidity: < 70% (non-condensing)
  • Storage temperature: 0 – 55°C
  • Relative humidity during storage: < 80% non-condensing
  • Dimensions:
    • Width 44 cm
    • Height 33 cm
    • Depth 15 cm
  • Weight: 2.5 kg
  • Risk class IIb
  • Electrical safety class I
Carboxytherapy Treatments

Treatments with our CARBO HPT device

Chest Treatment

Foot Treatment

Wrinkle Treatment

...